1. Definitions and Scope
1.1. A Home Inspection is a non-invasive visual
examination of a residential dwelling, performed
for a fee, which is designed to identify observed
material defects within specific components of said
dwelling. Components may include any combination
of mechanical, structural, electrical, plumbing,
or other essential systems or portions of the home,
as identified and agreed to by the Client and Inspector,
prior to the inspection process.
I. A Home Inspection is intended to assist in evaluation
of the overall condition of the dwelling. The inspection
is based on observation of the visible and apparent
condition of the structure and its components on
the date of the inspection and not the prediction
of future conditions.
II. A home inspection will not reveal every concern
that exists or ever could exist, but only those material
defects observed on the day of the inspection.
1.2. A Material Defect is a condition of
a residential real property or any portion of it
that would have a significant adverse impact on the
value of the real property or that involves an unreasonable
risk to people on the property. The fact that a structural
element, system or subsystem is near, at or beyond
the end of the normal useful life of such a structural
element, system or subsystem is not by itself a material
defect.
1.3. An Inspection report shall describe and identify
in written format the inspected systems, structures,
and components of the dwelling and shall identify
material defects observed. Inspection reports may
contain recommendations regarding conditions reported
or recommendations for correction, monitoring or
further evaluation by professionals, but this is
not required.
2. Standards of Practice
2.1. Roof
I. The inspector shall inspect from ground level
or eaves:
A. The roof covering.
B. The gutters.
C. The downspouts.
D. The vents, flashings, skylights, chimney and other
roof penetrations.
E. The general structure of the roof from the readily
accessible panels, doors or stairs.
II. The inspector is not required to:
A. Walk on any pitched roof surface.
B. Predict the service life expectancy.
C. Inspect underground downspout diverter drainage
pipes.
D. Remove snow, ice, debris or other conditions that
prohibit the observation of the roof surfaces.
E. Move insulation.
F. Inspect antennae, lightning arresters, de-icing
equipment, or similar attachments.
G. Walk on any roof areas that appear, in the opinion
of the inspector, to be unsafe.
H. Walk on any roof areas if it might, in the opinion
of the inspector, cause damage.
I. Perform a water test.
J. Warrant or certify the roof.
2.2. Exterior
I. The inspector shall inspect:
A. The siding, flashing and trim.
B. All exterior doors, decks, stoops, steps, stairs,
porches, railings, eaves, soffits and fascias.
C. And report as in need of repair any spacings between
intermediate balusters, spindles, or rails for steps,
stairways, balconies, and railings that permit the
passage of an object greater than four inches in
diameter.
D. A representative number of windows.
E. The vegetation, surface drainage and retaining
walls when these are likely to adversely affect the
structure.
F. And describe the exterior wall covering.
II. The inspector is not required to:
A. Inspect or operate screens, storm windows, shutters,
awnings, fences, outbuildings, or exterior accent
lighting.
B. Inspect items, including window and door flashings,
which are not visible or readily accessible from
the ground.
C. Inspect geological, geotechnical, hydrological
and/or soil conditions.
D. Inspect recreational facilities.
E. Inspect seawalls, break-walls and docks.
F. Inspect erosion control and earth stabilization
measures.
G. Inspect for safety type glass.
H. Inspect underground utilities.
I. Inspect underground items.
J. Inspect wells or springs.
K. Inspect solar systems.
L. Inspect swimming pools or spas.
M. Inspect septic systems or cesspools.
N. Inspect playground equipment.
O. Inspect sprinkler systems.
P. Inspect drain fields or drywells.
Q. Determine the integrity of the thermal window
seals or damaged glass.
2.3. Basement, Foundation & Crawlspace
I. The inspector shall inspect:
A. The basement.
B. The foundation
C. The crawlspace.
D. The visible structural components.
E. And report on the location of under-floor access
openings.
F. And report any present conditions or clear indications
of active water penetration observed by the inspector.
G. For wood in contact or near soil.
H. And report any general indications of foundation
movement that are observed by the inspector, such
as but not limited to sheetrock cracks, brick cracks,
out-of-square door frames or floor slopes.
I. And report on any cutting, notching and boring
of framing members which may present a structural
or safety concern.
II. The inspector is not required to:
A. Enter any crawlspaces that are not readily accessible
or where entry could cause damage or pose a hazard
to the inspector.
B. Move stored items or debris.
C. Operate sump pumps with inaccessible floats.
D. Identify size, spacing, span, location or determine
adequacy of foundation bolting, bracing, joists,
joist spans or support systems.
E. Provide any engineering or architectural service.
F. Report on the adequacy of any structural system
or component.
2.4. Heating
I. The inspector shall inspect:
A. The heating systems using normal operating
controls and describes the energy source and heating
method.
B. And report as in need of repair heating systems which
do not operate.
C. And report if the heating systems are deemed inaccessible
II. The inspector is not required to:
A. Inspect or evaluate interiors of flues or chimneys,
fire chambers, heat exchangers, humidifiers,
dehumidifiers, electronic air filters, solar heating
systems or fuel tanks.
B. Inspect underground fuel tanks.
C. Determine the uniformity, temperature, flow, balance,
distribution, size, capacity, BTU, or supply adequacy
of the heating system.
D. Light or ignite pilot flames.
E. Activate heating, heat pump systems, or other
heating systems when ambient temperatures or when
other circumstances are not conducive to safe operation
or may damage the equipment.
F. Override electronic thermostats.
G. Evaluate fuel quality.
H. Verify thermostat calibration, heat anticipation
or automatic setbacks, timers, programs or clocks.
2.5. Cooling
I. The inspector shall inspect:
A. The central cooling equipment using normal operating
controls.
II. The inspector is not required to:
A. Determine the uniformity, temperature, flow, balance,
distribution, size, capacity, BTU, or supply adequacy
of the cooling system.
B. Inspect window units, through-wall units, or electronic
air filters.
C. Operate equipment or systems if exterior temperature
is below 60 degrees Fahrenheit or when other circumstances
are not conducive to safe operation or may damage
the equipment.
D. Inspect or determine thermostat calibration, heat
anticipation or automatic setbacks or clocks.
E. Examine electrical current, coolant fluids or
gases, or coolant leakage.
2.6. Plumbing
I. The inspector shall:
A. Verify the presence of and identify the location
of the main water shutoff valve.
B. Inspect the water heating equipment, including
combustion air, venting, connections, energy sources,
seismic bracing, and verify the presence or absence
of temperature-pressure relief valves and/or Watts
210 valves.
C. Flush toilets.
D. Run water in sinks, tubs, and showers.
E. Inspect the interior water supply including all
fixtures and faucets.
F. Inspect the drain, waste and vent systems, including
all fixtures.
G. Describe any visible fuel storage
systems.
H. Inspect the drainage sump pumps and test pumps
with accessible floats.
I. Inspect and describe the water supply, drain,
waste and main fuel shut-off valves, as well as the
location of the water main and main fuel shut-off
valves.
J. Inspect and determine if the water supply is public
or private.
K. Inspect and report as in need of repair deficiencies
in the water supply by viewing the functional flow
in two fixtures operated simultaneously.
L. Inspect and report as in need of repair deficiencies
in installation and identification of hot and cold
faucets.
M. Inspect and report as in need of repair mechanical
drain-stops that are missing or do not operate if
installed in sinks, lavatories and tubs.
N. Inspect and report as in need of repair commodes
that have cracks in the ceramic material, are improperly
mounted on the floor, leak, or have tank components
which do not operate.
II. The inspector is not required to:
A. Light or ignite pilot flames.
B. Determine the size, temperature, age, life expectancy
or adequacy of the water heater.
C. Inspect interiors of flues or chimneys, water
softening or filtering systems, well pumps or tanks,
safety or shut-of valves, floor drains, lawn sprinkler
systems or fire sprinkler systems.
D. Determine the exact flow rate, volume, pressure,
temperature, or adequacy of the water supply.
E. Determine the water quality or pot ability or
the reliability of the water supply or source.
F. Open sealed plumbing access panels.
G. Inspect clothes washing machines or their connections.
H. Operate any main, branch or fixture valve.
I. Test shower pans, tub and shower surrounds or
enclosures for leakage.
J. Evaluate the compliance with local or state conservation
or energy standards, or the proper design or sizing
of any water, waste or venting components, fixtures
or piping.
K. Determine the effectiveness of anti-siphon, back-flow
prevention or drain-stop devices.
L. Determine whether there are sufficient clean-outs
for effective cleaning of drains.
M. Evaluate gas, liquid propane or oil storage tanks.
N. Inspect any private sewage waste disposal system
or component of.
O. Inspect water treatment systems or water filters.
P. Inspect water storage tanks, pressure pumps or
bladder tanks.
Q. Evaluate wait time to obtain hot water at fixtures,
or perform testing of any kind to water heater elements.
R. Evaluate or determine the adequacy of combustion
air.
S. Test, operate, open or close safety controls,
manual stop valves and/or temperature or pressure
relief valves.
T. Examine ancillary systems or components, such
as, but not limited to, those relating to solar water
heating, hot water circulation.
U. Determine the existence or condition of polybutylene
plumbing.
2.7. Electrical
I. The inspector shall inspect:
A. The service drop/lateral.
B. The meter socket enclosures.
C. The means for disconnecting the service main.
D. And determine the rating of the service
amperage.
E. Panel boards and over current devices (breakers
and fuses).
F. And report on any unused circuit breaker
panel openings that are not filled.
G. The service grounding and bonding.
H. A representative number of switches, receptacles,
lighting fixtures, AFCI protected receptacles.
I. And test all Ground Fault Circuit Interrupter
(GFCI) receptacles and GFCI circuit breakers observed
and deemed to be GFCI's during the inspection using
a GFCI tester.
J. And report the presence of solid conductor
aluminum branch circuit wiring if readily visible.
K. And report on any tested GFCI-tested receptacles
in which power was not present, polarity is
incorrect, is not secured to the wall, the cover
is not in place, the ground fault circuit interrupter
devices are not properly installed or do not operate
properly, evidence of arcing or excessive heat
is present, or where the receptacle is not grounded
or is not secured to the wall.
L. The service entrance conductors and the condition
of the conductor insulation.
M. And describe the amperage rating of the service.
N. And report the absence of smoke detectors.
O. Service entrance cables and report as in need
of repair deficiencies in the integrity of the insulation,
drip loop, or separation of conductors at weather
heads and clearances from grade or rooftops.
II. The inspector is not required to:
A. Insert any tool, probe or device into the main
panel board, sub-panels, distribution panel
boards, or electrical fixtures.
B. Operate electrical systems that are shut down.
C. Remove panel board cabinet covers or dead
front covers if they are not readily accessible.
D. Operate over current protection devices.
E. Operate non-accessible smoke detectors.
F. Measure or determine the amperage or voltage of
the main service equipment if not visibly labeled.
G. Inspect the fire or alarm system and components.
H. Inspect the ancillary wiring or remote control
devices.
I. Activate any electrical systems or branch circuits
which are not energized.
J. Operate or reset overload devices.
K. Inspect low voltage systems, electrical de-icing
tapes, swimming pool wiring or any time-controlled
devices.
L. Verify the service ground.
M. Inspect private or emergency electrical supply
sources, including but not limited to generators,
windmills, photovoltaic solar collectors, or battery
or electrical storage facility.
N. Inspect spark or lightning arrestors.
O. Inspect or test de-icing equipment.
P. Conduct voltage drop calculations.
Q. Determine the accuracy of labeling.
2.8. Fireplace
I. The inspector shall inspect:
A. The fireplace, and open and close the damper door
if readily accessible and operable.
B. Hearth extensions and other permanently installed
components.
C. And report as in need of repair deficiencies in
the lintel, hearth and material surrounding the fireplace,
including clearance from combustible materials
II. The inspector is not required to:
A. Inspect the flue or vent system.
B. Inspect the interior of chimneys or flues,
fire doors or screens, seals or gaskets, or
mantels.
C. Determine the need for a chimney sweep.
D. Operate gas fireplace inserts.
E. Light pilot flames.
F. Determine the appropriateness of any installation.
G. Inspect automatic fuel feed devices.
H. Inspect combustion and/or make-up air devices.
I. Inspect heat distribution assists whether gravity
controlled or fan assisted.
J. Ignite or extinguish fires.
K. Determine draft characteristics.
L. Move fireplace inserts, stoves, or firebox contents.
M. Determine adequacy of draft, perform a smoke test
or dismantle or remove any component.
N. Perform a National Fire Prevention Association
(NFPA) style inspection.
2.9. Attic, Ventilation & Insulation
I. The inspector shall inspect:
A. The insulation in unfinished spaces.
B. The ventilation of attic spaces.
C. Mechanical ventilation systems.
D. And report on the general absence or lack of insulation.
II. The inspector is not required to:
A. Enter the attic or any unfinished spaces that
are not readily accessible or where entry could cause
damage or pose a safety hazard to the inspector in
his or her opinion.
B. To move, touch, or disturb insulation.
C. To move, touch or disturb vapor retarders.
D. Break or otherwise damage the surface finish or
weather seal on or around access panels and covers.
E. Identify the composition or exact R-value
of insulation material.
F. Activate thermostatically operated fans.
G. Determine the types of materials used in insulation
or wrapping of pipes, ducts, jackets, boilers, and
wiring.
H. Determine the adequacy of ventilation.
2.10. Doors, Windows & Interior
I. The inspector shall:
A. Open and close a representative number of doors
and windows.
B. Inspect the walls, ceilings, steps, stairways,
and railings.
C. And report as in need of repair any spacing between
intermediate balusters, spindles, or rails for steps,
stairways, and railings that permits the passage
of an object greater than four inches in diameter.
D. Inspect garage doors and garage door openers by
operating first by remote (if available) and
then by the installed automatic door control.
E. And report as in need of repair any installed
electronic sensors that are not operable or not installed
at proper heights above the garage door.
F. And report as in need of repair any door locks
or side ropes that have not been removed or disabled
when garage door opener is in use.
G. And report as in need of repair any windows that
are obviously fogged or display other evidence of
broken seals.
II. The inspector is not required to:
A. Inspect paint, wallpaper, window treatments or
finish treatments.
B. Inspect central vacuum systems.
C. Inspect safety glazing.
D. Inspect security systems or components.
E. Evaluate the fastening of countertops, cabinets,
sink tops and fixtures, or firewall compromises.
F. Move furniture, stored items, or any coverings
like carpets or rugs in order to inspect the concealed
floor structure.
G. Move drop ceiling tiles.
H. Inspect or move any household appliances.
I. Inspect or operate equipment housed in the garage
except as otherwise noted.
J. Verify or certify safe operation of any auto reverse
or related safety function of a garage door.
K. Operate or evaluate any security bar release and
opening mechanisms, whether interior or exterior,
including their compliance with local, state, or
federal standards.
L. Operate any system, appliance or component that
requires the use of special keys, codes, combinations,
or devices.
M. Operate or evaluate self-cleaning oven cycles, tilt
guards/latches or signal lights.
N. Inspect microwave ovens or test leakage from microwave
ovens.
O. Operate or examine any sauna, steam-jenny, kiln,
toaster, ice-maker, coffee-maker, can-opener, bread-warmer,
blender, instant hot water dispenser, or other small,
ancillary devices.
P. Inspect elevators.
Q. Inspect remote controls.
R. Inspect appliances.
S. Inspect items not permanently installed.
T. Examine or operate any above-ground, movable,
freestanding, or otherwise non-permanently installed
pool/spa, recreational equipment or self-contained
equipment.
U. Come into contact with any pool or spa water in
order to determine the system structure or components.
V. Determine the adequacy of spa jet water force
or bubble effect.
W. Determine the structural integrity or leakage
of a pool or spa.
3. Limitations, Exceptions & Exclusions
3.1. Limitations:
I. An inspection is not technically exhaustive.
II. An inspection will not identify concealed or
latent defects.
III. An inspection will not deal with aesthetic concerns
or what could be deemed matters of taste, cosmetic
defects, etc.
IV. An inspection will not determine the suitability
of the property for any use.
V. An inspection does not determine the market value
of the property or its marketability.
VI. An inspection does not determine the insurability
of the property.
VI. An inspection does not determine the advisability
or inadvisability of the purchase of the inspected
property.
VIII. An inspection does not determine the life expectancy
of the property or any components or systems therein.
IX. An inspection does not include items not permanently
installed.
X. These Standards of Practice apply only to homes
with four or fewer dwelling units.
3.2. Exclusions:
I. The inspectors are not required to determine:
A. Property boundary lines or encroachments.
B. The condition of any component or system that
is not readily accessible.
C. The service life expectancy of any component or
system.
D. The size, capacity, BTU, performance, or efficiency
of any component or system.
E. The cause or reason of any condition.
F. The cause for the need of repair or replacement
of any system or component.
G. Future conditions.
H. Compliance with codes or regulations.
I. The presence of evidence of rodents, animals
or insects.
J. The presence of mold, mildew or fungus.
K. The presence of air-borne hazards.
L. The presence of birds.
M. The presence of other flora or fauna.
N. The air quality.
O. The existence of asbestos.
P. The existence of environmental hazards.
Q. The existence of electro-magnetic fields.
R. The presence of hazardous materials including,
but not limited to, the presence of lead in paint.
S. Any hazardous waste conditions.
T. Any manufacturer's recalls or conformance with
manufacturer installation or any information included for
consumer protection purposes.
U. Operating costs of systems.
V. Replacement or repair cost estimates.
W. The acoustical properties of any systems.
X. Estimates of the cost to operating any given
system.
II. The inspectors are not required to operate:
A. Any system that is shut down.
B. Any system that does not function properly.
C. Or evaluate low voltage electrical systems such
as, but not limited to:
1. Phone lines.
2. Cable lines.
3. Antennae.
4. Lights.
5. Remote controls.
D. Any system that does not turn on with the use
of normal operating controls.
E. Any shut off valves or manual stop valves.
F. Any electrical disconnect or over current protection
devices.
G. Any alarm systems.
III. The inspectors are not required to:
A. Move any personal items or other obstructions,
such as, but not limited to:
1. Throw rugs.
2. Furniture.
3. Floor or wall coverings.
4. Ceiling tiles
5. Window coverings.
6. Equipment.
7. Plants.
8. Ice.
9. Debris.
10. Snow.
11. Water.
12. Dirt.
13. Foliage.
14. Pets
B. Dismantle, open, or uncover any system or component.
C. Enter or access any area which may, in the opinion
of the inspector, be unsafe.
D. Enter crawlspaces or other areas that are unsafe
or not readily accessible.
E. Inspect underground items such as, but not limited
to, underground storage tanks or other indications
of their presence, whether abandoned or actively
used.
F. Do anything which, in the inspector's opinion,
is likely to be unsafe or dangerous to the inspector
or others or damage property, such as, but not limited
to, walking on roof surfaces, climbing ladders, entering
attic spaces or negotiating with pets.
G. Inspect decorative items.
H. Inspect common elements or areas in multi-unit
housing.
I. Inspect intercoms, speaker systems, radio-controlled,
security devices or lawn irrigation systems.
J. Offer guarantees or warranties.
K. Offer or perform any engineering services.
L. Offer or perform any trade or professional service
other than home inspection.
M. Research the history of the property, report on
its potential for alteration, modification, extendibility,
or its suitability for a specific or proposed use
for occupancy.
N. Determine the age of construction or installation
of any system structure or component of a building,
or differentiate between original construction and
subsequent additions, improvements, renovations or
replacements.
O. Determine the insurability of a property.
P. Perform or offer Phase 1 environmental audits.
Q. Inspect on any system or component which
is not included in these standards.
4. Glossary of Terms
4.1. Accessible: Can be approached or entered by
the inspector safely, without difficulty, fear or
danger.
4.2. Activate: To turn on, supply power, or enable
systems, equipment, or devices to become active by
normal operating controls. Examples include turning
on the gas or water supply valves to the fixtures
and appliances and activating electrical breakers
or fuses.
4.3. Adversely Affect: To constitute, or potentially
constitute, a negative or destructive impact.
4.4. Alarm System: Warning devices, installed or
free-standing, including but not limited to: carbon
monoxide detectors, flue gas and other spillage detectors,
security equipment, ejector pumps and smoke alarms.
4.5. Appliance: A household device operated by use
of electricity or gas. Not included in this definition
are components covered under central heating, central
cooling or plumbing.
4.6. Architectural Service: Any practice involving
the art and science of building design for construction
of any structure or grouping of structures and the
use of space within and surrounding the structures
or the design, design development, preparation of
construction contract documents, and administration
of the construction contract.
4.7. Component: A permanently installed or attached
fixture, element or part of a system.
4.8. Condition: The visible and conspicuous state
of being of an object.
4.9. Crawlspace: The area within the confines of
the foundation and between the ground and the underside
of the lowest floor structural component.
4.10. Decorative: Ornamental; not required for the
operation of essential systems and components of
a home.
4.11. Describe: To report in writing a system or
component by its type, or other observed characteristics,
to distinguish it from other components used for
the same purpose.
4.12. Determine: To arrive at an opinion or conclusion
pursuant to examination.
4.13. Dismantle: To open, take apart or remove any
component, device or piece that would not typically
be opened, taken apart or removed by an ordinary
occupant.
4.14. Engineering Service: Any professional service
or creative work requiring engineering education,
training, and experience and the application of special
knowledge of the mathematical, physical and engineering
sciences to such professional service or creative
work as consultation, investigation, evaluation,
planning, design and supervision of construction
for the purpose of assuring compliance with the specifications
and design, in conjunction with structures, buildings,
machines, equipment, works or processes.
4.15. Enter: To go into an area to observe visible
components.
4.16. Evaluate: To assess the systems, structures
or components of a dwelling.
4.17. Examine: To visually look. See Inspect.
4.18. Foundation: The base upon which the structure
or wall rests; usually masonry, concrete, or stone,
and generally partially underground.
4.19. Function: The action for which an item, component,
or system is specially fitted or used or for which
an item, component or system exists; to be in action
or perform a task.
4.20. Functional: Performing, or able to perform,
a function.
4.21. Home Inspection: The process by which an inspector
visually examines the readily accessible systems
and components of a home and operates those systems
and components utilizing these Standards of Practice
as a guideline.
4.22. Household Appliances: Kitchen and laundry appliances,
room air conditioners, and similar appliances.
4.23. Inspect: To visually look at readily accessible
systems and components safely, using normal operating
controls and accessing readily accessible panels
and areas in accordance with these Standards of Practice.
4.24. Inspected Property: The readily accessible
areas of the buildings, site, items, components,
and systems included in the inspection.
4.25. Inspector: One who performs a real estate inspection.
4.26. Installed: Attached or connected such that
the installed item requires tool for removal.
4.27. Material Defect: A condition of
a residential real property or any portion of it
that would have a significant adverse impact on the
value of the real property or that involves an unreasonable
risk to people on the property. The fact that a structural
element, system or subsystem is near, at or beyond
the end of the normal useful life of such a structural
element, system or subsystem is not by itself a material
defect.
4.28. Normal Operating Controls: Devices such as
thermostats that would be operated by ordinary occupants
which require no specialized skill or knowledge.
4.29. Observe: To see through visually directed attention.
4.30. Operate: To cause systems to function or turn
on with normal operating controls.
4.31. Readily Accessible: An item or component is
readily accessible if, in the judgment of the inspector,
it is capable of being safely observed without the
removal of obstacles, detachment or disengagement
of connecting or securing devices, or other unsafe
or difficult procedures to gain access.
4.32. Recreational Facilities: Spas, saunas, steam
baths, swimming pools, tennis courts, playground
equipment, and other exercise, entertainment or athletic
facilities.
4.33. Report: A written communication (possibly including images)
of any material defects seen during the inspection.
4.34. Representative Number: A sufficient number
to serve as a typical or characteristic example of
the item(s) inspected.
4.35. Safety Glazing: Tempered glass, laminated glass,
or rigid plastic.
4.36. Shut Down: Turned off, unplugged, inactive,
not in service, not operational, etc.
4.37. Structural Component: A component which supports
non-variable forces or weights (dead loads) and variable
forces or weights (live loads).
4.38. System: An assembly of various components which
function as a whole.
4.39. Technically Exhaustive: A comprehensive and
detailed examination beyond the scope of a real estate
home inspection which would involve or include, but
would not be limited to: dismantling, specialized
knowledge or training, special equipment, measurements,
calculations, testing, research, analysis or other
means.
4.40. Unsafe: A condition in a system or component
which is judged to be a significant risk of personal
injury during normal, day-to-day use. The risk may
be due to damage, deterioration, improper installation
or a change in accepted residential construction
standards.
4.41. Verify: To confirm or substantiate.
The aforementioned terms are found within the Standards
of Practice. Visit
InterNACHI's full Glossary.
|
 |

905-371-4229



|